Illustrated title card for the guide: Emporia Vue 3 vs IoTaWatt vs HomeWizard P1
comparison

Emporia Vue 3 vs IoTaWatt vs HomeWizard P1

Compare Emporia Vue 3, IoTaWatt, and HomeWizard P1 for circuit detail, local data and history. See which fits your electrical panel or smart meter.

Choose IoTaWatt for circuit readings and history on your local network. Choose the Emporia Vue 3 for circuit readings in Emporia’s cloud-connected app. Choose the HomeWizard P1 for local readings from a compatible smart meter, down to individual phases when the meter supplies them. IoTaWatt data visualization, Emporia Vue architecture, HomeWizard P1 fields.

Compare data access and circuit detail

MonitorWhat it measuresWhere you read it
Emporia Vue 3Panel mains and up to 16 monitored branch circuits through current transformers (CTs).Live readings and history in the Emporia Energy app via the cloud. The Vue 3 has no built-in local API. Vue features
IoTaWattCTs on selected mains and circuits. One input is reserved for voltage, and 14 other inputs can take power or voltage measurements.Circuit history on the device, with JSON or CSV downloads through the query API and local charts on releases that support Graph+. Inputs, local history
HomeWizard P1Smart-meter fields can include whole-meter power, cumulative energy import and export, and individual phase readings.Latest reading via a local API. For a local time series, record the readings in your own logger. Available fields, history limits

Count the inputs you need

  • Vue 3. List the branch circuits you want to track. The Vue has up to 16 branch CT connections, with separate connections for the mains. Once the monitor is set up, use Menu → Manage Devices → your Vue monitor → Circuits to name each connected circuit by port and assign its type. Emporia hardware guide
  • IoTaWatt. In the documented split-phase setup with one voltage reference and one CT on each main, the two mains use two of the 14 flexible inputs. That leaves 14 − 2 = 12 inputs for branch CTs if none are used for additional voltage references. Count sensors for your panel layout, since some loads can use more than one CT. IoTaWatt inputs, split-phase setup
  • HomeWizard P1. A phase reading gives you the total for that phase. For separate readings on branch circuits that share a phase, include each circuit in your sensor count for the Vue 3 or IoTaWatt. P1 readings, Vue circuit readings, IoTaWatt inputs

If you’re unfamiliar with panel work, have a qualified electrician handle it. The service mains can stay energized with the main breaker off. Emporia safety guidance, IoTaWatt installation guidance.

Check what you can read locally

Vue 3. Ethernet and 2.4 GHz Wi-Fi are connection options. Both use Emporia’s cloud for data access. During an internet outage, the app cannot read the Vue directly. Emporia says the Vue buffers measurements during interruptions under about 15 minutes. For longer outages, it reports an approximate average over the outage window after reconnection. Network options, cloud access, outage behavior.

IoTaWatt. On a configured unit that supports Graph+, open http://iotawatt.local/graph2.htm from your local network, substituting its local hostname or IP address if different. Select Watts, then select your circuit to plot power. Select Wh and the circuit to plot energy. IoTaWatt calls for an internet-connected network to run the configuration utility or when the device clock is unset. Graph+ controls, Wi-Fi setup.

HomeWizard P1. For local-only operation, the v2 API supports setting cloud_enabled to false with PUT /api/system. With the cloud disabled, the HomeWizard app loses access to the device and the P1 Meter stops receiving firmware updates. HomeWizard cloud controls.

Check your smart meter and read the P1 locally

  1. Look up your country and meter model in HomeWizard’s compatibility guide. Check the port and whether your model needs an adapter, external power, or port activation. HomeWizard compatibility guide

  2. Connect the P1 Meter to Wi-Fi through the HomeWizard app. Use a client on the same network and find the meter’s local IP address. Local API setup

  3. For a P1 Meter that supports API v2, replace METER_IP in both requests below. If the meter returns user:creation-not-enabled, press the P1 Meter’s button once and repeat the request promptly. Keep the returned token private. Follow HomeWizard’s guidance for validating the device certificate and hostname. Token pairing, HomeWizard authorization

    curl https://METER_IP/api/user --insecure -X POST \
      -H 'Content-Type: application/json' -H 'X-Api-Version: 2' \
      -d '{"name":"local/new_user"}'
  4. Replace YOUR_TOKEN with the token from the previous step and read the latest measurement. power_w is total active power in watts. power_l1_w, power_l2_w, and power_l3_w are phase readings when present. Unavailable fields are omitted. HomeWizard versioned request, P1 measurement fields

    curl https://METER_IP/api/measurement --insecure \
      -H 'Authorization: Bearer YOUR_TOKEN' -H 'X-Api-Version: 2'

Evidence and limits. Emporia’s Vue Gen 3 help, IoTaWatt’s documentation labeled 02_03_20, and HomeWizard’s P1 and API v2 documentation were checked on November 26, 2026. The steps were not run on hardware.

Sources

  1. Emporia: How Your Vue Works
  2. Emporia: Hardware and Wire Harness Installation
  3. Emporia: Vue Offline Behavior
  4. IoTaWatt: Installation
  5. IoTaWatt: Split-Phase Installation
  6. IoTaWatt: Data Visualization
  7. IoTaWatt: Graph+
  8. IoTaWatt: Connecting to WiFi
  9. HomeWizard: Smart Meter Compatibility
  10. HomeWizard: Local API Introduction
  11. HomeWizard API v2: Authorization
  12. HomeWizard: API Versioning and Updates
  13. HomeWizard API v2: Recent Measurement
  14. HomeWizard API v2: System
  15. HomeWizard: Getting Started with the Local API

Related