CT Clamp Sizes for 200A Main Panels, 15A–50A Branch Circuits

Choose CT clamps for a 200A main panel and 15A to 50A branch circuits by checking rated current, the clamp opening, and monitor compatibility.

For a 200A main panel, start with a current transformer (CT) rated for at least 200A if you want to measure up to the full panel rating. For a 15A to 50A branch circuit, apply the same check to the individual circuit rating. Then check the clamp opening against the insulated conductor diameter and confirm that the monitor supports the CT model.

How CT sizing rules work

A split-core CT has a core that opens. Use the stated aperture dimensions to judge fit. For a round aperture, compare its diameter with the conductor’s specified insulated outside diameter. OpenEnergyMonitor’s CT installation documentation

Sizing table for 200A mains and 15A to 50A branch circuits

Use the current you want to measure up to as the minimum rated primary current in your search. The table shows this comparison when your target is the full circuit rating.

Measurement targetMinimum rated primary current
200A main panel200A
15A branch circuit15A
20A branch circuit20A
30A branch circuit30A
40A branch circuit40A
50A branch circuit50A

For example, Shelly rates its CT 120A for a maximum primary current of 120 A. That falls short of the full 200A measurement target. For a 50A target, it passes the current rating check. The aperture and monitor compatibility still need to be checked. Shelly CT 120A specifications

Checking monitor output compatibility before buying

A current-output CT needs a burden, which can be a resistor. A voltage-output CT has its burden resistor built in. Check the monitor’s supported output type and connector together. OpenEnergyMonitor’s CT sensor introduction and CT installation documentation

Published CT exampleWhat to check against the monitor documentation
YHDC SCT-013-000Current output. Its secondary has 2000 turns, so the secondary current is one 2000th of the primary current. OpenEnergyMonitor’s CT sensor introduction
Shelly CT 120AListed for the Shelly Pro 3EM with a 2-pin MX3.0-2x1Y connector. Shelly CT 120A specifications

Pre-order checklist

  1. Current range. Compare the rated primary current with the top of your measurement range. For small loads, check the candidate’s published accuracy range at the low end too. Shelly CT 120A specifications and OpenEnergyMonitor’s CT installation documentation
  2. Clamp opening. Check the candidate’s aperture against the insulated outside diameter. Shelly lists the CT 120A’s aperture as Ø15 mm and gives the clamp body’s dimensions separately. Shelly CT 120A specifications
  3. Meter compatibility. Check the supported signal type, connector and sensor model in the meter maker’s documentation. OpenEnergyMonitor’s CT sensor introduction and Shelly CT 120A specifications

Installation follows the equipment maker’s manual and local rules.

Browse all Energy Monitor Lab guides.

Evidence and limits

OpenEnergyMonitor’s CT sensor documentation and Shelly’s CT 120A specifications were checked on 2026-11-27. No hardware was tested or installed for this guide.

Sources

  1. OpenEnergyMonitor: CT Sensors Introduction
  2. OpenEnergyMonitor: Current Transformer Installation
  3. Shelly Knowledge Base: CT 120A